www.gsg-analytical.com
Wer wir sindUnser AngebotWir helfen Ihnen weiterWie Sie uns finden

VOC-ident

 

VOC-ident

The new fast and highly sensitive identification method of gases and gas mixtures by an array of different gas sensors. By a statistical pattern recognition following the principal "good-bad" or "yes-no" the system will be trained to a classification of gaseous compounds. Organized by a PCA analysis the measurement readings created by the sensors will be classified in certain cluster which clearly represent a distinction.

This gas sensors-based technology ensures the routine application throughout the process and quality control of food as well as the environmental analysis in real-time and on-line.

 

The Modular Concept - The Research-grade VOC-ident System

 

MOSES II:

  • changeable combined sensor modules
  • future development integration

    Specifications:
    Sensor modules:
    QMB-Module (8 quartz micro balance sensors), MOS-Module (8 metal oxide semiconductor sensors)

    Entrance modules:
    pump
    mass flow controller
    temperature sensor
    humidity sensors

 

The Compact Concept - The Routine VOC-ident Systems

 

VOCmeter:

  • combination with conventional sampling systemes (Headspace Autosampler)
  • active sampling by integrated pump
  • small, manageable, compact
  • small dead volume
  • fixed number of sensors

    Specifications:
    Sensors: QMB-Module (8 quartz micro balance sensors) and MOS-Module (4 metal oxide semiconductor sensors)
    Dimensions (WxHxD): 120x60x260 mm, Weight: 1.600 g.

VOCvario:

  • maximum flexibility
  • up to 8 variable sensors
  • variable positioning of sensors
  • small, manageable, compact
  • small dead volume

    Specifications:
    Sensors: up to 8 individual sensors
    Cable length: standard length 1m, Maximum length for MOS 10m, QMB 100m
    Dimensions (WxHxD): 120x60x190 mm, Weight: 800 g., Weight sensors: 50 - 200 g.

VOCcheck:

  • hand-held sensor system
  • active sampling
  • easy to handle
  • fast results

    Specifications:
    Sensors: 4 QMB-Modules (quartz micro balance sensors)
    Software: on-board
    Weight: 400 g. (incl. Accu)

 

 

GSG MultiSens Software for VOC ident-Systems

 

GSG MultiSens:

  • interactive data analysis
  • multiple algorithmen
  • support for many sensor systems
  • extensive data export

GSG MultiSens Analyser:

  • one software for all data types
  • interactive analysis
  • comprehensive analysis options
  • extensive graphical options
  • basic und standard version available

 

Advantages of the VOC-ident Technology:

Objectivity: It does not know the difference between pleasant and unpleasant odours; the judgement is unbiased.

Reproducibility: It is much less subject to fatigue than the human nose. Even after many days of continuous operation, results remain comparable.

Long term capability: See above; additionally: long term survey (e.g. to cope with odour nuisances caused by agricultural or industrial facilities) are not feasible with human "sniffers". The VOC-ident systems can sample the air for days or weeks and create an objective log.

Routine tasks : Well-trained "sniffers" are rare and expensive, normally too expensive for routine jobs such as quality control of raw materials. The VOC-ident systems, however, excels at such tasks.

 

 

further information

 

 

| Responsibility | Help | Home ]

© 2002· GSG Mess- und Analysengeräte GmbH
Im Technologiedorf 9 · D-76646 Bruchsal
Fon ++49 (0)7251/ 98 19 -0 · Fax ++49 (0)7251/ 98 19 -19
saleseur@gsg-analytical.com · www.gsg-analytical.com